Home > Product > FQZ integrated test-bed of generator-starter of ve |
|
FQZ-series test-bed is mainly used for testing of the manufacture process of the generator under 3Kw of domestic and foreign vehicles and the experiment of all the performances, and it can also be applied in the experiment equipment for vehicle repair. It has excellences such as fast, safe and reliable montage fixture, displays of the test results by Intelligent Digital Meter, maintenance of test data for the starter test, set functions of coefficient for M.m meter and rpm meter, a accuracy measurement, a true reflection of the starter and generator parameters and so on
|
Main technical parameter of generator (FQZ-2) Measuring range | 3kW under 24V | Power supply | AC 50Hz\380V (3 phases,4 wires) | Fixing method | Pneumatic adjustable | Method of inverter adjusting | Manual | Speed adjusting range | Empty load 0-6000r/min、load 0-6000r/min | Rotation direction of generator | Positive and reverse | Control of electronic load box | Manual 0-200A/12V、0-100A/24V | Digital instrument display | Current, Voltage, Rotation speed | Main technical parameter of starter (FQZ-2) Testing range | Under 10kW | Power supply | AC 220伏、50Hz(Battery supply for experiment to be prepared by user itself) | Fixing method | Manual adjustable | Starter load | Hydraulic braking by foot control | Digital instrument display | Current, voltage, torque, rotation speed,maintenance of test data | Torque measuring range | 0-200N·m | set functions of coefficient for M.m meter and rpm meter |
|
|
|
|